Case Report

Hand Microsurg. 2012; 1(1): 40-42


Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report

Tolga Eryılmaz, Ali Çağrı Tekin, Şafak Uygur.

Abstract
Two-staged flexor tendon repair rely on the effect of the pseudo-tendon sheath that developed by the effect of the silicone tendon prosthesis. The second stage of the reconstruction is performed 1 to 6 months after the first operation by removal of the silicone tendon prosthesis and tendon grafting. In this study, we are presenting a removal of silicone prosthesis 6 years after insertion for flexor tendon reconstruction.

Key words: Hunter prosthesis, silicone tendon prosthesis, two-staged flexor tendon reconstruction


Full text links

Share this Article


Advertisement
Journal of Molecular Pathophysiology

SUBMIT YOUR ARTICLE NOW




ScopeMed Home
Follow ScopeMed on Twitter
BiblioCAM
Article Tools
eJPort Journal Hosting
About ScopeMed
Terms & Conditions
Privacy Policy
Suggest a Journal
Publisher Login
Contact Us

The articles in Scopemed are open access articles licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.