Home|Journals Follow on Twitter| Subscribe to List

Directory for Medical Articles
 

Open Access

23

J App Pharm Sci. 2014; 4(9): 036-045


Simultaneous Determination of Oxyclozanide and Levamisole by Spectrophotometric and Chromatographic Methods

Afaf Osman Mohamed, Nesrin Khamees Ramadan, Sara Essa Shawky, Maissa Yaaqub Salem.

Abstract
Three simple, accurate and sensitive methods were developed for simultaneous determination of oxyclozanide and levamisole. Method (A) was depending on zero-order absorption spectrophotometry for measuring oxyclozanide at 300 nm and derivative ratio spectrophotometry for levamisole using oxyclozanide as a divisor, then measuring the peak amplitude at 246 nm. Method (B) was TLC method, using silica gel 60 F254 plates; the optimized mobile phase was ethyl acetate/ methanol/ ammonium hydroxide 33% (8:2:0.2 by volume). The spots were scanned densitometrically at 300 nm for oxyclozanide and 220 nm for levamisole. Method (C) was an HPLC method, performed on C18 column using acetonitrile/ methanol/ 0.05M potassium dihydrogen phosphate (60:20:20 by volume), the pH was adjusted to 3.5±0.2 with ortho-phosphoric acid as a mobile phase with a flow rate of 1 ml/min. Detection was performed at 220 nm. Linearity ranges were 5 – 40 µg/ml of oxyclozanide and levamisole for method (A), 1 – 6 µg/band of oxyclozanide and 2 - 10 µg/ band of levamisole for method (B) and 0.5 – 10 µg/ml of both drugs for method (C), the mean percentage recoveries were 100.21±0.844% for oxyclozanide and 99.53±0.920% for levamisole in case of method (A), 99.72±1.348% for oxyclozanide and 99.14±1.277% for levamisole in case of method (B) and 99.81±0.852% for oxyclozanide and 100.20±0.886% for levamisole in case of method (C). The proposed methods were found to be specific for both drugs in their binary mixture. Statistical comparison between the results obtained by these methods and the manufacturer’s method for oxyclozanide and the official method for levamisole was done, and no significance difference was observed.

Key words: Oxyclozanide; levamisole; suspension; spectrophotometry; HPLC; TLC



Share this Article


Advertisement
Journal of Environmental and Occupational Science

SUBMIT YOUR ARTICLE NOW


ScopeMed.com
ScopeMed Home
Follow ScopeMed on Twitter
BiblioCAM
Author Tools
eJPort Journal Hosting
About ScopeMed
License Information
Terms & Conditions
Privacy Policy
Suggest a Journal
Publisher Login
Contact Us

The articles in Scopemed are open access articles licensed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (https://creativecommons.org/licenses/by-nc-sa/4.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
ScopeMed is a Database Service for Scientific Publications. Copyright © ScopeMed® Information Services.
Scopemed Buttons